Jump to: • Sewer • Potable Water • Reclaimed Water • Miscellaneous • Roadway • Storm Drainage
Click on the file icons below to download specific files.
 S-1 Sanitary Sewer Design Notes
 S-2 Sanitary Sewer Construction Notes
 S-3 Lift Station Wet Well Design Notes
 S-4 Lift Station Wet Well Construction Notes
 S-5 Sanitary Sewer Approved Products
S-6 Standard Manhole
S-7 Sanitary Sewer Cover and General Notes
S-8 Shallow Manhole
S-9 Outside Drop Manhole (Standard New Construction)
S-10 Outside Drop Manhole (Standard)
S-11 Outside Drop Manhole (Retrofit Only)
S-12 Inside Drop Manhole (Retrofit Only)
S-13 Rubber Boot and Precast Joint Connection
S-14 Storm Drainage Crossing/Sanitary Lateral Pipe Crossing
S-15 Sewer Lateral
S-16 Cleanout
S-17 Locator Tape/Tracewire Installation for Sewer Water and Reclaimed Water Pipelines
S-18 Sewer/Water/Drainage Crossing
S-19 Typical Lift Station Site Plan
S-20 Typical Lift Station Site Plan
S-21 Lift Station Potable Water Service (Where Reclaim Water Not Available)
S-22 Lift Station Wet Well
S-23 Lift Station Emergency Pump Connection
S-24 Packaged Lift Station Electrical Equipment Rack
S-25 Packaged Lift Station Electrical Service Schematic
S-26 Sanitary Sewer Force Main Valve and Valve Box
S-27 Type A Bedding and Trench (Special Gravity Sewer Installations)
S-28 Type B Bedding and Trench (Typical for Water, Sewer, Forcemain, Stormdrain, and Reclaimed Water Main Installation)
S-29 Sanitary Sewer Double Manhole Cover
S-30 Standard Air Release Valve Assembly (Vertical Pipe Layout)
S-31 Sewer Air Release Valve Assembly with Odor Control System (Vertical Pipe Layout)
S-32 Standard Air Release Valve Assembly Above Ground Vertical Pipe Layout
S-33 Sewer Air Release Valve Assembly with Odor Control System and Cover Above Ground Offset Pipe Layout
S-34 Air Release Valve Underground (Force Mains) Traffic Style
 
Potable Water Details
Jump to: • Sewer • Potable Water • Reclaimed Water • Miscellaneous • Roadway • Storm Drainage
Click on the file icons below to download specific files.
 W-1 Potable Water Design Notes
 W-2 Potable Water Construction Notes
 W-3 Potable Water Approved Products
W-4 Fire Hydrant Assembly
W-5 Potable Water Valve and Valve Box (4-16-inch Valve Sizes)
W-6 Tapping Valve and Sleeve
W-7 Air Release Valve Pit
W-8 Meter Box Layout
W-9 Water Service (Meter Sizes 3/4-1 inch)
W-10 Multiple Water Services Connection Detail for Commercial Use Only
W-11 Water Service (Meter Sizes 1 or 2 inch)
W-12 Water Service with Backflow Preventer (Meter Sizes 3 or 8 inch)
W-13 Potable Water Blow Off Assembly
W-14 PVC to HDPE Restrained Joint
W-15 Backflow Preventer (Reduced Pressure) 3-8 inch
W-16 2 inch Backflow Preventer
W-17 Conduit Crossing R.R. or Roadway
W-18 Conduit Crossing R.R. or Roadway
W-19 Storm Drainage Pipe or Sanitary Sewer Main Conflict
W-20 Storm Drainage Pipe or Sanitary Sewer Main Conflict
W-21 Main Installation Between Drainage Inlet and Sidewalk
W-22 Non-Standard Water Meter Box (Meter 3 inch and Larger Sizes)
W-23 3-8 inch Water Meter Box
W-24 Trough Frame Pedestrian Loading Access Single Door
W-25 Trough Frame Pedestrian Loading Access Double Door
W-26 Access Door Cross Reference Chart
W-27 Temporary Jumper Connection
W-28 Contractors' Installation Requirements for a 2 inch Temporary Meter
W-29 Locator Tape/Tracewire Installation for Water Main Pipelines
 
Reclaimed Water Details
Jump to: • Sewer • Potable Water • Reclaimed Water • Miscellaneous • Roadway • Storm Drainage
Click on the file icons below to download specific files.
 RW-1 Reclaimed Water Design Notes
 RW-2 Reclaimed Water Construction Notes
 RW-3 Reclaimed Water Approved Products
RW-4 Reclaimed Water Meter Mox Layout
RW-5 Reclaimed Water Service: Irrigation (Sprinkler) Connection
RW-6 Reclaimed Water Lateral Service: (2 inch Meter)
RW-7 Reclaimed Water Service: Single Service (C.D.R. Meter Box)
RW-8 Reclaimed Water Service: Double Service (C.D.R. Meter Box)
RW-9 Reclaimed Water Main Valve Box
RW-10 Reclaimed Water Blow-Off
RW-11 Reclaimed Water Valve andValve Box (4-16 inch Valve Sizes)
RW-12 Locator Tape/Tracerwire Installation for Reclaimed Water, Pipelines
 
Miscellaneous Details
Jump to: • Sewer • Potable Water • Reclaimed Water • Miscellaneous • Roadway • Storm Drainage
Click on the file icons below to download specific files.
 M-1 Requirements for As-Built Drawings
M-2 Plan Sheet Requirements
M-3 Sidewalk Construction Requirements
M-4 Sidewalk and Bike Path Ramp
M-5 Sidewalk and Bike Path Ramp
M-6 Driveway Apron
M-7 Private Parking Lot
M-8 Concrete Wheel Stop
M-9 Road Barricade
M-10 Handicap Accessible Parking Spaces
M-11 Handicap Accessible Parking Spaces
M-12 Handicap Sign
M-13 Dumpster Pad
M-14 Street and Walkway Lights
  M-15 Reserved
M-16 Street and Walkway Lights 'Gardco Lighting'
M-17 Street and Walkway Lights 'Lumec Lighting'
M-18 Sidewalk Construction at Intersections
M-19 Sidewalk Construction at Intersections
M-20 Fiber Optic Cable & Handholes
M-21 Fiber Optic Cable & Handholes Notes
M-22 Stabilized Walking Path
M-23 One and Two Family Residential Grading Lot
M-24 Street and Walkway Lights 'Traditional Post Top'
M-25 Temporary Construction Fence
 
Roadway Details
Jump to: • Sewer • Potable Water • Reclaimed Water • Miscellaneous • Roadway • Storm Drainage
Click on the file icons below to download specific files.
R-1 50' or 60' R/W Road Section
R-2 60' R/W with Ditch Road Section
R-3A 80' R/W with Median and Ditch Road Section
R-3B 80' R/W with Median and Ditch Road Section
R-4A 100' R/W with 5 Lane Road Section
R-4B 100' R/W with 5 Lane Road Section
R-5 100' R/W with 4 Lane and Median Road Section
R-6 Roadway Geometry
R-7 Standard Cul-de-sac Detail with Single Storm Inlet
R-8 Standard Cul-de-sac Detail with Double Storm Inlet
R-9 Standard Curb Construction
R-10 Roadway Intersection Valley Gutter
R-11 Pavement Butt Joint
R-12 Roadway and Parking Area Design and Construction Notes
R-13 Roadway and Parking Area Design and Construction Notes
R-14 Roadway and Parking Area Design and Construction Notes
R-15 Roadway and Parking Area Design and Construction Notes
R-16 Roadway and Parking Area Design and Construction Notes
R-17 Roadway and Parking Area Design and Construction Notes
R-18 Technical Specifications for Site Plans and Subdiv. Testing
R-19 Concrete Pavement Details
R-20 Subdivision Technical Specifications; Sodding, Seeding and Mulching
R-21A Roadway and Miscellaneous Landscaping Design and Construction Notes
R-21B Roadway and Miscellaneous Landscaping Design and Construction Notes
R-22 Silt Fence Turbidity Barrier
R-23 Tree Protection Barricade
R-24 Floating Turbidity Barrier
R-25 Contractor Requirements for Site Clearing, Grading, and Erosion Control Design and Construction Notes
R-26 Contractor Requirements for Site Clearing, Grading, and Erosion Control Design and Construction Notes
R-27 Temporary Gravel Construction Entrance
 
Storm Drainage Details
Jump to: • Sewer • Potable Water • Reclaimed Water • Miscellaneous • Roadway • Storm Drainage
Click on the file icons below to download specific files.
ST-1 Storm Inlet Apron
ST-2 Concrete Spillway
ST-3 Pavement Trench Restoration
ST-4 Storm Drainage Design and Construction Notes
ST-5 Storm Drainage Design and Construction Notes
ST-6 Storm Drainage Design and Construction Notes
ST-7 Canal and Waterway Design and Construction Notes
ST-8 Bridge Design and Construction Notes
ST-9 Dry Retention Pond
ST-10 Wet Retention Pond
ST-11 Type C Storm Inlet
ST-12 Type E Storm Inlet
 
Important Numbers
Main Number
386-506-5500

Customer Service
(Water / Sewer/ Garbage Bill Questions & Payments)
386-506-5720

Community Development & Building Permits
386-506-5600

Code Compliance Hotline
386-506-5604

Fire Administration
386-506-5900

Parks & Recreation
386-506-5850

Parks & Recreation Afterhours
386-756-7400

Police Department
386-506-5800

Police Non-Emergency & Animal Control
386-756-7400

Public Utilities
386-506-5750

Public Utilities Afterhours
386-756-5380

Public Works
386-506-5575

Public Works Afterhours
386-756-7400

City Manager,
Mayor & City Council

386-506-5501

Click here to go to the Stormwater Management page


City Tweets
Police Tweets
668.6076. Public records status of e-mail addresses; agency website notice: Under Florida law, e-mail addresses are public records. If you do not want your e-mail address released in response to a public records request, do not send electronic mail to this entity. Instead, contact this office by phone or in writing.